Brand Name : Honeywell
Model Number : 621-9937C
Certification : COC
Place of Origin : USA
MOQ : 1 Piece
Price : inquiry
Payment Terms : T/T
Supply Ability : 10 Piece per a day
Delivery Time : 3-5 work days
Packaging Details : original
Product Name : Honeywell 621-9937C Parallel I/O Module Processor Rack Power Supply
Product Model : 621-9937C
Condition : New
Shipping : DHL,TNT or EMS,Fedex,UPS
Stock : Available
Warranty : 12 months
Rating : 24Vdc, 110mA
Packing Size : 11.8" x 7.9" x 9.9" (30 cm x 20 cm x 25 cm)
Gross Weight : 3kg
Honeywell 621-9937C Parallel I/O Module Processor Rack Power Supply
Product Details:
| Brand Name | Honeywell | 
| Model | 621-9937C | 
| Catalog | TDC2000 | 
| Origin | United States (USA) | 
| Dimension | 30*25*20cm | 
| Weight | 3kg | 
| HS Code | 8537101190 | 
| Payment | T/T | 
| Sales Price | $2000 | 
| Warranty | 12 months | 
| Lead time | 3-5 work days | 
  Additional Information:
| POWER DISTR.CABLE PDB-0824 TO FTA 24V 2A | 7023_Safety Management System Hardware | 
| POWER DISTRIBUTION CABLE SET CPCHAS-0001 | 7023_Safety Management System Hardware | 
| POWER DISTR.BOARD EXT IO CABINET 5VDC WD | 7023_Safety Management System Hardware | 
| POWER DISTR.BOARD CONTROLLER CAB 5VDC WD | 7023_Safety Management System Hardware | 
| MIGRATION CABLE SET FSC TO SM CONTROLLER | 7023_Safety Management System Hardware | 
  Description:
While the processor is in the DISABLE mode, the RUN LED is turned ON. The scan loss timer is cleared at the beginning of every PLC scan unless a timeout occurs. If a timeout occurs, the RUN LED is
turned OFF.
All local I/0 are cleared or frozen according to the DIP switch settings on the processor board. The hardware of the processor module sends a power fail signal to the I/0 system. Outputs are cleared or held in the last state in the DISABLE mode, depending on the PIOM setting for each I/0 rack and the processor module DIP switch selections.
FORCE functions are permissible if they are ENABLED by the processor DIP switches. Timer and counter modifications may be made.
To change the processor from the DISABLE mode to any other mode of operation, one of the following conditions must be met: 1) the keyswitch is changed, 2) the Loader /Terminal generates a request for Software Program Mode, 3) a CIM generates a Software Program Mode request, or 4) the processor fails diagnostics and defaults to the Diagnostics Fail Mode.

|   | 
| Honeywell 621-9937C Parallel I/O Module Processor Rack Power Supply Images | 
 TC-IAH061 Honeywell Experion Analog Input Module PCL Module In Stock
                                                                                    
                        
                        
                        
                                                            TC-IAH061 Honeywell Experion Analog Input Module PCL Module In Stock
                                                    
                        
                     TC-IDD321 Honeywell Experion LS I/O Specifications 32 Digital DC Input Module
                                                                                    
                        
                        
                        
                                                            TC-IDD321 Honeywell Experion LS I/O Specifications 32 Digital DC Input Module
                                                    
                        
                     FS-IO-0001 Honeywell Input / Output Extender Module PLC Control System
                                                                                    
                        
                        
                        
                                                            FS-IO-0001 Honeywell Input / Output Extender Module PLC Control System
                                                    
                        
                     TC-IDJ161 Honeywell Digital Input Module Discrete DC Module In Stock
                                                                                    
                        
                        
                        
                                                            TC-IDJ161 Honeywell Digital Input Module Discrete DC Module In Stock
                                                    
                        
                     TC-IXL061 Honeywell Thermocouple PLC Input Module Brand New In Stock
                                                                                    
                        
                        
                        
                                                            TC-IXL061 Honeywell Thermocouple PLC Input Module Brand New In Stock
                                                    
                        
                     MU-TAIH12 Honeywell High Level Analog Input/STI FTA PLC Module In Stock
                                                                                    
                        
                        
                        
                                                            MU-TAIH12 Honeywell High Level Analog Input/STI FTA PLC Module In Stock
                                                    
                        
                     TC-IXR061 Honeywell Experion Analog Input Module DCS Module PLC Module
                                                                                    
                        
                        
                        
                                                            TC-IXR061 Honeywell Experion Analog Input Module DCS Module PLC Module
                                                    
                        
                     FC-SDOL-0424 Hoenywell Digital Output Module Original
                                                                                    
                        
                        
                        
                                                            FC-SDOL-0424 Hoenywell Digital Output Module Original
                                                    
                        
                     TC-ODD321 Honeywell Experion DC Output Module PLC Module Brand New
                                                                                    
                        
                        
                        
                                                            TC-ODD321 Honeywell Experion DC Output Module PLC Module Brand New
                                                    
                        
                     MU-TAIL02 Honeywell Low Level Analog Input Module Termination Board Brand New
                                                                                    
                        
                        
                        
                                                            MU-TAIL02 Honeywell Low Level Analog Input Module Termination Board Brand New